This tutorial presents the sizing and construction of an electrical system for a solar generator (1 kWp or ‘kilowatt peak’) which can be moved by bicycle. This structure was designed to fit on the CHARRETTE, an assisted trailer designed by the Véloma association whose plans are freely available.
This tutorial presents the sizing and construction of an electrical system for a solar generator (1 kWp or ‘kilowatt peak’) which can be moved by bicycle. This structure was designed to fit on the CHARRETTE, an assisted trailer designed by the Véloma association whose plans are freely available.
générateur, remorque, remorque solaire, générateur mobile, panneaux solaires, photovoltaique, seconde main
This trailer is a functional demonstration designed as a part of the Scholar Grid project.
Supported and piloted by the Fondation Schneider Electric in partnership with these associations Low-tech Lab,Énergies sans Frontières and Atelier 21, this project intends to investigate innovative solutions to provide affordable and clean electric energy to training centers that train future electricians. The energy systems created by the technical experts and the teachers of the training centers, will be implemented by students and serve as a pedagogical base.
The fields of investigation of this project were the following:
To test these techniques in real conditions, Low-tech Lab constructed a mobile generator trailer. With the power of 1kW, it combines the repaired second hand solar panels and the regenerated lead batteries. This was designed on the basis of concrete needs: to provide electricity for the Festival Low-tech organized in Concarneau in July of 2022.
Beginning with this concrete case, "the tutorial details the general steps of sizing a photovoltaic installation in self-consumption". The context, the preliminary evaluation of needs and the choice of adapted energy sources are explained in detail in the document "An energy-autonomous Festival?’ In the ‘Files’ section".
This tutorial is addressed to people with a basic level of knowledge in electricity and in the components of photovoltaic installation. If that is not your case, do not hesitate to release the basics via E-leaning of INES (in English) or via the GuidEnR Photovoltaic website. (Links in the ‘Notes and references’ section). Warning: This tutorial does not cover the basic notions of electricity and the associated safety instructions. These manipulations can become very dangerous! It is your responsibility to ensure you work safely.
Quantity | Designation | New Material Price | Project Material Price (donation, second-hand, reclaimed) | ||||
---|---|---|---|---|---|---|---|
3 | Peimar 330W Solar Pannel | 500 | 105 | ||||
1 | Victor Energy Phoenix 24V/1200VA Inverter | 503 | 200 | ||||
1 | Schneider Electric Connext 60A/150V MPPT charge controller | 650 | 0 | 12 | Hawker 4PzS240 traction battery - 2V 240Ah | 1980 | 650 |
1 | Victron Energy BMV700 battery controller + crimped cable + wall bracket + VE Direct Bluetooth Smart Dongle | 250 | 250 | ||||
1 | Fuse MEGA-Fuse 125A / 32V (x5) + Fuse holder MEGA Victron Energy | 33 | 33 | ||||
1 | Schneider Electric C120N 125A Circuit Breaker | 320 | 0 | ||||
2 | Schneider Electric iC60N 63A Circuit Breaker | 25 | 0 | ||||
1 | Schneider Electric Resi9 10A Circuit Breaker | 15 | 0 | ||||
1 | Schneider Electric 30mA/40A differential Circuit Breaker | 90 | 0 | ||||
16m | 1x4mm² red/black solar cable with MC4 connector | 24 | 0 | ||||
1 | Male MC4 Connector | 4 | 0 | ||||
1 | Female MC4 Connector | 4 | 0 | ||||
6m | Red / blue / green-yellow cable 1x16mm² | 16 | 16 | ||||
6 | Tubular battery terminal 16mm²-12 | 4 | 4 | ||||
2 | Tubular battery terminal 35mm² - 10 | 2,6 | 2,6 | ||||
6 | Gray PG16 cable gland + Washer | 11,5 | 11,5 | ||||
6 | Gray PG11 cable gland + Washer | 9,5 | 9,5 | 1 | Bloc multiprise extérieur IP44 | 14 | 14 |
TOTAL | 4442 € (~4,764.22 $USD) | 1282 € (~1,375.00 $USD) |
The cheapest and cleanest energy is that which we do not produce/consume!
In line with this principle, this approachnégaWatt proposes to rethink our vision of energy by applying a three step approach: Sobriety, Efficiency, then renewable energy. Before sizing a photovoltaic electrical installation, it is necessary to consider several questions:
What are my needs? Which are essential and incompressible? Is electricity the most efficient way to meet all these needs?
Detail on these questions applied to the case of our Festival is available in the "Files" tab located above.
To materialize the electricity consumption of everyday equipment and possibly be able to eventually prioritize, the open-source game REVOLT translates these consumptions in pedaling time.
Me: "'This step is the most important of an autonomous photovoltaic sizing'". It will have a big influence on the price, autonomy, and the durability of the installation.
This step will permit you to see where your "'large electrical consumption items"' are located and to make choices accordingly. (Ex: An electric oven demands 5000W of power. Is electrical energy the most pertinent to respond to this need?)
It is recommended to not under estimate your needs and to always consider the worst case!
Example: A rainy day, during a week-end, in winter. The entire family is present. The lights are on 9 hours a day. They want to eat hot food. Lots of activities are happening inside.
Several softwares can help you in sizing a solar installation. We have used the free software CalcPvAutonome developed by David Mercereau. A interface dédiée lets you calculate your daily electrical needs. We came up with what we call an ‘’’Energy audit (simplified).
The principle is simple:
We listed all the equipment being used We indicate their power (In Watts, W) We indicate the duration of their daily use (in hour/day, h/d) We determine if certain equipment is capable of functioning simultaneously The tool gives us a daily energy consumption (in watt per hour by day, W.h/d)
-Look on the manual or the tag on the device itself. If you only have the voltage U (In Volts, V) and the intensity I (In Amps, A), you can calculate it: P=U x I
-Get a Wattmeter (~10.73 $USD). It is connected between the socket and the device and tells you precisely its power.
{{Warning l Certain devices do not consume the same quantity of energy all the time. For example, even if a refrigerator is permanently plugged in, it does not consume energy until the interior temperature passes a certain level.
There is also the option to enter the energy consumption manually. For that, you have to measure it! Connect a Wattmeter-Consometer to the equipment for 1 to 7 days to have the actual daily consumption (see image).}}
In the case of our Festival, we have thus evaluated our electrical needs (see image) :
Daily electrical needs: 4080Wh/d
Maximum electrical power need: 177W
We have deliberately chosen to "not fuel the power hungry devices"' "'in energy by electricity"' !
>The kitchen (for 100 people) was made using a wood-burning stove.
> To serve fresh beverages, we have agreed to a partnership with the Concarneau auction that permanently produces ice and stored it in an unplugged freezer (vs.4800Wh/d). In the same way, the beer taps are frozen directly with the ice and stay disconnected (vs 5600Wh/d). |Step_Picture_00=Remorque_g_n_ratrice_solaire_-_Syst_me__lectrique_Screenshot_2022-08-31_at_10-41-01_CalcPvAutonome_Calculer_dimensionner_son_installation_photovolta_que_isol_e_autonome_.png }}
Once the energy needs are entered in CalcPVAutonome, several important parameters must be entered for the sizing.
If you have an idea about the location of the SP related to local technique, specify these distances. If in doubt, overestimate a little.
Specify your location. The average radiation data per month is calculated via the database PVGIS.
Once the parameters are entered, we begin the calculation!
CalcPVAutonome Proposes an estimate of necessary material in accordance with these parameters. This is given for information only and must be analyzed. In our case, we have readjusted accordingly with the material already available to us that we used.
To satisfy our daily needs of 4080Wh/d, a minimal SP power of 937W is required (detailed calculations done by the software). The software tells us that 5 monocrystalline panels of 190W would work.
But 5 panels were too cumbersome for our trailer + we already had 1 solar panel of 330W. We have chosen 3 panels of 330W for a total power of 990W.
Generally, the voltage of a battery pack is determined in accordance with the power of the SP:
In our case, we have 990W of SP, therefore the final voltage of our battery pack will be 24V.
To allow an autonomy of 8 hours (~0.3d), the software calculates that the nominal capacity of batteries of 170Ah en C10. (See detailed calculation in image)
However, to ensure the longevity of the battery packs, their charging current must not exceed 20% of their normal capacity. (See Operation, maintenance and regeneration of lead acid batteries)
That is: 170 x 20% = 34A.
Or, with 990W of SP the charging current is 990 / 24 = 41,25A.
You can choose to restrict the production of SP thanks to the charge regulator, but generally we advise you to increase the capacity of the battery packs in consequence. So here, 41,25 x 100 / 20 = 206Ah.
Having found a good opportunity, we have finally opted for the purchase of a set of battery packs Operation, maintenance and regeneration of lead acid batteries l regenerated traction batteries of 240Ah. It consists of 12 240Ah-2V batteries assembled in a series to have a voltage of 24V. This will raise our autonomy to 10 hours.
The characteristics of the charge regulator are determined in accordance with the characteristics of the maximum current leaving the SP. We therefore need the characteristics of SP given by their technical file or on the back of the panels. It is necessary to know the " Open Circuit Voltage " (Voc) and the "Intensity of Short-Circuit Current " (Isc) of SP.
In our case, for each panel: Voc= 40,49V and Isc= 10,25A
When adding the panels in series: Voc_tot= 121,5V et Isc_tot= 10,25A
In taking safety margins of 20%, a 150V 20A MPPT regulator might have been suitable.
Having had the opportunity to recover a "'Conext MPPT 150V/60A regulator"', we opted for this model.
The choice of converter is decided in accordance with the power that the installation must deliver (in AC) and in accordance with the voltage of the battery pack
We wanted to be able to occasionally power devices up to 1000W.
We have opted for a "'Victron 24V/1200VA"' converter that increases the maximum output power of 1200W with possible peaks up to 2400W.
To know the charging state of our batteries and to prolong their lifespan, we have chosen to use a battery monitor (strongly recommended).
-Isolating and breaking devices ("'circuit breaker and/or switch - disconnector"') must be installed in different places to install and maintain the system safely : -Between the SP and the charge controller -Between the charge controller and batteries -Between the batteries and the inverter -Between the batteries and the DC loads
The devices are placed on the 2 polarities (+ and -)
-Overcurrent protective devices ("'fuses or circuit breakers"') must be installed to protect the equipment from high current conditions: --At the SP output, on the two polarities (+ and -), against the risks of overcurrent under the forme of courant retour. Not necessary, if you have only one channel of SP in series. -At the battery output, on the +, against the high discharge currents.
"'Between the SP and the charge controller:"'
Between the charge regulator, the inverter and the batteries:
Iop étant le courant en opération. Il diffère si on est en mode charge ou décharge des batteries :
On choisit la valeur maximale donc Ifuse>104 A. Nous avons choisi un fusible MEGA 125A 32V de chez Victron Energy.
Pour éviter des pertes par échauffement, voire des risques d'incendie, il est important de bien dimensionner tous les câbles de l'installation. C'est-à-dire, calculer la section minimale (en mm²) du câble.
La formule est la suivante :
S > ρ*2*L*I / ε*U
For this you need to know:
Entre les PV et le régulateur de charge | Entre le régulateur de charge et les batteries | Entre les batteries et l'onduleur |
---|---|---|
S > 0,023*2*4* 10,25 / 121,5*0,01 | S > 0,023*2*1* 1000 / 24*24*0,01 | S > 0,023*2*0,5* 2400 / 24*24*0,01 |
S> 1,55mm² | S>7,9mm² | S>9,5mm² |
A partir des sections calculées, il convient ensuite de choisir la section commerciale supérieure :
Entre les PV et le régulateur de charge | Entre le régulateur de charge et les batteries | Entre les batteries et l'onduleur |
---|---|---|
S = 2,5mm² | S= 10mm² | S=10 ou 16 mm² |
On peut vérifier les valeurs d'intensité maximale admissible correspondant à ces sections dans des abaques (voir image).